Daily maintenance of shaking incubator :
  
Since such instruments are often in contact with water and gas, impurities in the gas may enter the gas pipeline, causing the machine not to work properly. Daily work needs to be maintained from the following aspects:
  
1, always check the water level of the water jacket, if the water level is low, add water;
  
2, regular inspection of carbon dioxide cylinders, carbon dioxide cylinders can not be used empty;
  
3, check the carbon dioxide gas supply pipe and the interface has no leakage;
  
4. Dust the machine regularly to prevent dust from blocking air passages and solenoid valves.
  
   Oscillating incubator maintenance and care:
  
1. Observe daily whether the incubator temperature meets the regulations. Abnormalities should be found and repaired by professionals in a timely manner.
  
2. When the lighting in the cabinet is abnormal, replace the lighting fixture in time.
  
3. When the abnormal heating (cooling) is found, check whether the heating wire (compressor) is damaged and repair it in time after damage.
  
4. Clean the incubator in a timely manner to keep it clean and clean. Apply sterile water once a week to thoroughly clean the incubator liner. Change different types of disinfectant water every quarter to avoid producing resistant strains.
  
5. Perform a performance verification on this equipment every year.
  
6. Before using this equipment, check carefully whether the power supply voltage and the instrument requirements are consistent.
  
7. When the device is not in use, set the control switches to a non-operating state and cut off the power supply.
  
     Oscillating incubator maintenance and care:
  
1. The incubator enclosure should be reliably grounded.
  
2. Incubator should be placed in a cool, dry, well ventilated place away from heat and sunlight. Keep it steady to prevent vibrations from generating noise.
  
3. In order to ensure that the condenser can effectively dissipate heat, the distance between the condenser and the wall should be greater than 100mm, the side of the box should have a 50mm gap, and the top of the box should have at least 300mm space.
  
4. The incubator should avoid collision, shaking and shaking when carrying, repairing and maintaining. The maximum inclination is less than 45 degrees.
  
5, the instrument suddenly does not work, please check the fuse tube (after the box) is burned, check the power supply.
  
6. When the incubator is working in refrigeration, the difference between the temperature in the cabinet and the ambient temperature should not be greater than 25 degrees.
  
7. Illumination time can be programmed and controlled by the “programmable timerâ€. For the programming method, refer to the "Programmable Time Controller" instruction.
  
   Oscillating incubator maintenance:
  
1. During the continuous operation of the instrument, regular inspections shall be conducted every three months; check the fuses, control components and fastening screws, and if any water droplets, dirt, etc. shall fall into the motor and control elements.
  
2. The bearing of the transmission part has been filled with a proper amount of grease before leaving the factory. During the continuous operation of the instrument, grease should be filled once every six months. The filling volume accounts for about 1/3 of the bearing space.
  
3, the compressor should avoid continuous start
  
4, the instrument is used regularly, natural wear is a normal phenomenon. After one year of use of the instrument, if abnormal noises are found in the motor and compressor, the bearings of the transmission part are worn out, the belt is loose or cracked, and the electronic control element fails, the company will continue to provide excellent service and assist.
  
  