Let us find out more about the
dehumidifier and air-conditioning dehumidification function, the independent dehumidification mode of the air-conditioning uses electric heating or heat exchange to heat the outlet air, the control will be more complicated, the design cost is relatively high, but this temperature compensation will make Room temperature fluctuations are relatively small, suitable for use when the temperature is not high but the humidity is too high. The air conditioner operates in an independent dehumidification mode, the refrigeration system is in a highly efficient state, the evaporator and condenser operating conditions are reasonable, and the energy efficiency ratio is high.
The dehumidifier 's working method is to reduce the temperature inside the machine, analyze the water in the air, the temperature of the space will rise slightly, but the temperature difference is not obvious, it is more suitable for the humid season outside the midsummer, and the electricity consumption is relatively saved.
However, for the dehumidifier , when the ambient temperature is lower than 15°C, the water droplets adhering to the evaporator surface will freeze and the dehumidification effect will be weakened. If the ambient temperature exceeds 40°C, the pressure in the system will increase to overload the compressor. At this time, the overload protector should cut off the line, otherwise the compressor motor will be damaged. Therefore, the dehumidifier's excellent use temperature range is 15 °C ~ 40 °C.
  Can the air conditioner not dehumidify it? With air conditioning, does the dehumidifier become redundant? In fact, this is a consumer misunderstanding.
     The main function of the air conditioner is cooling and heating, heat the air and heat into sensible heat (latent heat), the air conditioner refrigerant is mainly sensible heat carried away in the air, the temperature of the room drops, and a small decrease limit The loss of moisture (humid heat) in the air, so that the air does not become excessively dry, making people feel uncomfortable; while the air conditioner with independent dehumidification function, although it can dehumidify, but the dehumidification is small, dehumidification is slow, and during the rainy season, the temperature Generally around 20°C, the air blown by the independent dehumidification function of the air conditioner is a cold air. The lower the dehumidification temperature is, the lower the dew point temperature of the air is. As the temperature approaches the surface temperature of the evaporator, the temperature difference becomes smaller and the dehumidification becomes worse. . In addition, because the air conditioner is a fixed type, it can only dehumidify in a small area , and more importantly, when the air conditioner operates an independent dehumidification function, the load operation is increased several times, not only the power consumption is large, but also the compression is easy. Machine damage, shorten the life of the machine.
    The main function of the dehumidifier is dehumidified, the main take up moisture when the air dehumidifier is working, due to the special structure of the dehumidifier constructed so hot and humid air is effectively translated into sensible heat, so that hot air is blown dehumidifier, so as to effectively enhance the The dew point temperature of the air, the temperature difference becomes larger, the dehumidification increases, plus the heat generated when the machine works, so as to effectively increase the ambient temperature of the room, and the air after the temperature rise is cooled by the dehumidifier, so that the moisture in the air The maximum limit was drawn. In addition, the increase in the temperature of the air environment, so that the air in the case of no increase in the moisture content, so that the relative humidity of the air to reduce, thereby greatly reducing the relative humidity of the air; dehumidifier is mobile, so easier to goods targeted Storage. Therefore, air conditioners should not be used in place of dehumidifiers .